Auburn Ambulance Station Fitout
This involved CFD odour modelling to ensure that occupants of adjacent apartment building would experience no odour nuisance outside their balconies.
Veritech grease filters and COANDA hoods were used to ensure that no grease or odour (below compliance) is exhausted into the local atmosphere.
Client: | Ambient Services Group |
Work Type: | Fitout Design. Design for Sub Contractors, Performance Approach |
Sector: | Hospitality (e.g., fast food store, cafe, restaurant, hotel, resort, pub, casino) |
Size: | 600sqm |
Disciplines Engaged: | Mechanical |
The Challenges Faced
The building is surrounded by apartment building as well, which imposed a large risk of causing acoustic and odour nuisance to neighbouring building.
The Solution Provided
With the limited electrical power supply, energy efficiency was in mind during the design. Energy recovery system that provided 100% outside air into the space while harvesting waste energy from exhaust air. Additionally, a heat recovery VRF system was designed to allow for high comfort levels along with relatively low energy consumption.
Our BIM skills have been utilised to 3D model the mechanical services ahead of the installation to avoid clashes and keep rework to a complete minimum